Trunk Near-End LOF Alarm
This alarm is applicable only to products supporting digital (BRI or PRI) interfaces (Mediant 500, Mediant 500L, Mediant 800, Mediant 1000 and Mediant 3100).
acTrunksAlarmNearEndLOF
|
Alarm |
acTrunksAlarmNearEndLOF |
||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
OID |
1.3.6.1.4.1.5003.9.10.1.21.2.0.50 |
||||||||||||||||||||
|
Default Severity |
Critical |
||||||||||||||||||||
|
Source Varbind Text |
Interfaces#0/Trunk#<m>, where m is the trunk interface number, 1 being the first trunk |
||||||||||||||||||||
|
Event Type |
communicationsAlarm |
||||||||||||||||||||
|
Probable Cause |
lossOfFrame |
||||||||||||||||||||
|
Severity |
Condition |
Text |
Corrective Action |
||||||||||||||||||
|
Critical |
Near end LOF |
"Trunk LOF Alarm" |
|
||||||||||||||||||
|
Cleared |
End of LOF |
- |
- |
||||||||||||||||||